SpaceMaster™esp

  • SM 3000 Series
    SM 3000
    • Operation mode and max sensing range:
      • Thru-beam: 1-15 m
    • Cable or plug connection
    • Sensitivity adjustment via control input
    • Wide variety of housings
    • Power and output indicator
    • High voltage tolerance to hostile environments
    • 10-30 V dc supply voltage
    • 3 wire, NPN or PNP transistor output
    • Test input
    • UL325 approved series optionally available (see datasheet for SM 3000 U series in Downloads)
    • Available with optional ATEX approval
      (II 3 G Ex nA IIC T6 Gc and II 3D Ex tc IIIC T100 ºC Dc)

    Ver

  • SM 3000/CAT2 Series
    SM 3000/CAT2
    • Operation mode and max sensing range:
      • Thru beam: 1-10 m
    • Cable or plug connection
    • Sensitivity adjustment via control input
    • Power and output indicator 
    • 10-30 V dc supply voltage
    • 3 wire, NPN or PNP transistor output
    • Narrow optical beam
    • TUV approved as safety device (AOPD) for power operated doors and gates acc. EN12978

    Ver

  • SM 6000 Series
    SM 6000
    • Operation mode and max sensing range:
      • Thru-beam: 1-6 m
    • Cable or plug connection
    • Sensitivity adjustment via control input
    • Wide variety of housings
    • Power and output indicators
    • High tolerance to hostile environments
    • 10-32 V dc supply voltage
    • 3 wire, NPN or PNP output or 4 wire, NPN/PNP opto isolated output
    • 5 or 0,5 ms response time
    • Low current consumption
    • Test input
    • Available with optional ATEX approval
      (II 3 G Ex nA IIC T6 Gc and II 3D Ex tc IIIC T100 ºC Dc)

    Ver

  • SM 7000 Series
    SM 7000
    • Operation mode and max sensing range:
      • Thru-beam: 0-20 m
      • Diffuse proximity: 0-1 m
      • Retro reflective: 0-3 m
      • Fibre: Dependent on the fibre optic
    • Cable or Plug connection
    • Sensitivity adjustment via potentiometer
    • Switch selectable light or dark function
    • Power and output indicators
    • High tolerance to hostile environments
    • 10-30 V dc supply voltage
    • 4 wire, NPN/PNP transistor output or 4 wire, ambivalent PNP/PNP transistor output
    • Test input

    Ver

  • SM 8000 Series
    SM 8000
    • Operation mode and max sensing range:
      • Thru-beam: 0-20 m
      • Diffuse proximity: 0-1 m
      • Retro reflective: 0-3 m
      • Fibre: Dependent on fibre optic
    • Cable or plug connection
    • Sensitivity adjustment via potentiometer
    • Switch selectable light or dark function
    • Power and output indicators
    • High tolerance to hostile environments
    • 10-30 V dc or 20-250 V ac supply voltage
    • 3 wire, NPN or PNP transistor output or 2 wire, SCR output
    • Test input
    • Available with optional ATEX approval
      (II 3 G Ex nA IIC T6 Gc and II 3D Ex tc IIIC T100 ºC Dc)

    Ver

  • SM 9000
    SM 9000
    • Operation mode and max range:
      • Thru-beam: 0-70 m
    • Cable or plug connection
    • Sensitivity adjustment via control input
    • Power and output indicators
    • High tolerance to hostile environments
    • 10-30 V dc supply voltage
    • Available outputs:
      • NPN transistor output
      • PNP transistor output
      • Solid state output
    • Test input
    • High excess gain
    • IP 69K rating
    • Optical cross talk elimination of 4 independent sensor channels selectable via wire connection
    • Available with optional ATEX approval
      (II 3 G Ex nA IIC T6 Gc and II 3D Ex tc IIIC T100 ºC Dc) or
      UL Hazloc compliant (Class II, Division 2, Groups F and G)

    Ver

  • SM 7000-IO Series
    SM 7000-IO
    • Operation mode and max sensing range:
      • Thru-beam: 0-20 m
      • Diffuse proximity: 0-1 m
      • Retro reflective: 0,1-3 m
      • Fibre: Dependent on the fibre optic
    • IO-Link communication interface
    • IO-Link PC software for parameter configuration and diagnostics
    • M8 or M12 plug connection
    • Sensitivity adjustment via potentiometer
    • Switch selectable light or dark function
    • Power and output indicators
    • High tolerance to hostile environments
    • 10-30 V dc supply voltage
    • 4 pin, IO-Link / push-pull and NPN or PNP output
    • Test input

    Ver

  • SM 9000-IO Series
    SM 9000-IO
    • Operation mode and max sensing range:
      • Thru-beam: 0-70 m
    • IO-Link communication interface
    • PC software for parameter configuration and
      diagnostics with optional USB-IO-Link Master 02
    • M12 plug connection
    • Transmitting power adjustment
    • Power and output indicators
    • High tolerance to hostile environments
    • 10-30 V dc supply voltage
    • 5 pin, IO-Link / push-pull and NPN or PNP output
    • Test input
    • High excess gain
    • IP 69K rating
    • Optical cross talk elimination of 4 independent
      sensor channels selectable via IO-Link

    Ver

Busca Rápida

O

Buscador de productos

Spanish Lorem ipsum dolor sit amet, consectetur adipiscing elit. Phasellus finibus et dolor eu tempor. In faucibus consectetur magna, vehicula porta leo accumsan eget. In faucibus consectetur magna, vehicula porta leo accumsan eget.

Abrir Buscador de productos

Contact Us

Get in touch with Telco by clicking here and filling out our contact form. One of our dedicated representatives will get back to you shortly

Contáctenos

Catalogue

Download our Catalogue

Fill out the contact form to receive a digital or hard copy of the complete Main Catalogue from Telco.

Formulario de contacto

We use cookies to personalize content and to analyze our traffic. Please decide if you are willing to accept cookies from our website.